Availability: | |
---|---|
Quantity: | |
Dirkbiel
Enkonduko:
The Liquid Tank Seal HEPA is an air filtration equipment that combines liquid trough sealing technology with high-efficiency filtration media. It achieves a tight connection between the filter and the frame by setting a liquid trough within the frame of the filter, utilizing the sealing property of the liquid to effectively prevent unfiltered air from entering the clean area through gaps.
Application:
It is installed at the end air supply outlet of clean rooms, FFU and clean equipment and air supply systems with high requirements (electronics, bio-pharmaceutical medical ,chemical,)
Advantage:
●Large dust capacity
●Large ventilation
●High structural strength
●Low resistance
●Long service life
Enkonduko:
The Liquid Tank Seal HEPA is an air filtration equipment that combines liquid trough sealing technology with high-efficiency filtration media. It achieves a tight connection between the filter and the frame by setting a liquid trough within the frame of the filter, utilizing the sealing property of the liquid to effectively prevent unfiltered air from entering the clean area through gaps.
Application:
It is installed at the end air supply outlet of clean rooms, FFU and clean equipment and air supply systems with high requirements (electronics, bio-pharmaceutical medical ,chemical,)
Advantage:
●Large dust capacity
●Large ventilation
●High structural strength
●Low resistance
●Long service life
Specification:
Attributes | Value | |||
Frame | Aluminum alloy | |||
Filter material | Glass fiber filter paper | |||
Filter Material separation | Hot mel | |||
Efficiency | EN 1822 | H13 | ||
ASHRAE | MERV17-18 | |||
Temperature | ≤80℃ | |||
Humidity | ≤80% RH | |||
Recommended Max. Final Pressureiz drop | ≤ 580Pa | |||
Groove width | 19mm |
Technical Data Sheet:
Model | Actual Size (mm) | Filtration area(㎡) | Airflow / initial resistance (m³/h / Pa) | Efficiency EN1822 | ||||
Width | Heigh | Thickness | 0.3 m/s | 0.35 m/s | 0.45 m/s | |||
DMAX-U-P1005 | 320 | 320 | 90 | 3.8 | 120/80 | 180/90 | 280/120 | U15 |
DMAX-U-P1006 | 475 | 475 | 90 | 6.8 | 200 /80 | 280/90 | 350/120 | U15 |
DMAX-U-P1007 | 484 | 484 | 90 | 7.5 | 220/80 | 300/90 | 400/120 | U15 |
DMAX-U-P1008 | 570 | 570 | 90 | 12.2 | 320/80 | 400/90 | 500/120 | U15 |
DMAX-U-P1009 | 610 | 610 | 90 | 15.5 | 400/80 | 500/90 | 650/120 | U15 |
DMAX-U-P1010 | 305 | 610 | 90 | 7.5 | 200/80 | 250/90 | 350/120 | U15 |
DMAX-U-P1011 | 630 | 630 | 90 | 15.4 | 650 /80 | 1150/90 | 1500/120 | U15 |
DMAX-U-P1012 | 762 | 610 | 90 | 17.5 | 550 /80 | 650/90 | 800/120 | U15 |
DMAX-U-P1013 | 915 | 610 | 90 | 23 | 650 /80 | 750/90 | 950/120 | U15 |
DMAX-U-P1014 | 1170 | 570 | 90 | 28.5 | 800 /80 | 1800/90 | 2400/120 | U15 |
DMAX-U-P1015 | 1170 | 870 | 90 | 42 | 1200 /80 | 1350/90 | 1700/120 | U15 |
DMAX-U-P1016 | 1220 | 610 | 90 | 30.5 | 850 /80 | 1000/90 | 1450/120 | U15 |
DMAX-U-P1017 | 915 | 915 | 90 | 34.8 | 950/80 | 1100/90 | 1400/120 | U15 |
DMAX-U-P1018 | 1170 | 1170 | 90 | 56.5 | 1500 /80 | 1750/90 | 2300/120 | U15 |
DMAX-U-P1019 | 1220 | 915 | 90 | 46.2 | 1200 /80 | 1400 /90 | 1800 /120 | U15 |
Specification:
Attributes | Value | |||
Frame | Aluminum alloy | |||
Filter material | Glass fiber filter paper | |||
Filter Material separation | Hot mel | |||
Efficiency | EN 1822 | H13 | ||
ASHRAE | MERV17-18 | |||
Temperature | ≤80℃ | |||
Humidity | ≤80% RH | |||
Recommended Max. Final Pressureiz drop | ≤ 580Pa | |||
Groove width | 19mm |
Technical Data Sheet:
Model | Actual Size (mm) | Filtration area(㎡) | Airflow / initial resistance (m³/h / Pa) | Efficiency EN1822 | ||||
Width | Heigh | Thickness | 0.3 m/s | 0.35 m/s | 0.45 m/s | |||
DMAX-U-P1005 | 320 | 320 | 90 | 3.8 | 120/80 | 180/90 | 280/120 | U15 |
DMAX-U-P1006 | 475 | 475 | 90 | 6.8 | 200 /80 | 280/90 | 350/120 | U15 |
DMAX-U-P1007 | 484 | 484 | 90 | 7.5 | 220/80 | 300/90 | 400/120 | U15 |
DMAX-U-P1008 | 570 | 570 | 90 | 12.2 | 320/80 | 400/90 | 500/120 | U15 |
DMAX-U-P1009 | 610 | 610 | 90 | 15.5 | 400/80 | 500/90 | 650/120 | U15 |
DMAX-U-P1010 | 305 | 610 | 90 | 7.5 | 200/80 | 250/90 | 350/120 | U15 |
DMAX-U-P1011 | 630 | 630 | 90 | 15.4 | 650 /80 | 1150/90 | 1500/120 | U15 |
DMAX-U-P1012 | 762 | 610 | 90 | 17.5 | 550 /80 | 650/90 | 800/120 | U15 |
DMAX-U-P1013 | 915 | 610 | 90 | 23 | 650 /80 | 750/90 | 950/120 | U15 |
DMAX-U-P1014 | 1170 | 570 | 90 | 28.5 | 800 /80 | 1800/90 | 2400/120 | U15 |
DMAX-U-P1015 | 1170 | 870 | 90 | 42 | 1200 /80 | 1350/90 | 1700/120 | U15 |
DMAX-U-P1016 | 1220 | 610 | 90 | 30.5 | 850 /80 | 1000/90 | 1450/120 | U15 |
DMAX-U-P1017 | 915 | 915 | 90 | 34.8 | 950/80 | 1100/90 | 1400/120 | U15 |
DMAX-U-P1018 | 1170 | 1170 | 90 | 56.5 | 1500 /80 | 1750/90 | 2300/120 | U15 |
DMAX-U-P1019 | 1220 | 915 | 90 | 46.2 | 1200 /80 | 1400 /90 | 1800 /120 | U15 |
High Pleat
28 pleats per 100 mm, higher pleats can also be customized
Dry and Wet Otional
Dry: gasket / Wet: Jelly glue
Durable
Filter paper has high strength, moisture resistance and durability
Double Gard Net
Double-sided protective mesh is more durable
High Pleat
28 pleats per 100 mm, higher pleats can also be customized
Dry and Wet Otional
Dry: gasket / Wet: Jelly glue
Durable
Filter paper has high strength, moisture resistance and durability
Double Gard Net
Double-sided protective mesh is more durable