Key Technologies and Implementation Strategies for Hospital Cleanroom Design

I. Classification and Standards of Cleanrooms

Hospital cleanrooms are classified into four levels (A, B, C, D) based on usage and cleanliness requirements (referring to GB/T 16297-1996 "Air Cleanliness Standard"), with Level A having the highest cleanliness suitable for sterile operating rooms and transplant wards. Each level has specific requirements for air cleanliness, airflow organization, and pressure differential (Table 1). For example, Level A requires ≥0.5μm particle concentration ≤3.5 particles/L, vertical unidirectional airflow, and indoor positive pressure difference maintained at +10Pa to +15Pa.
Cleanliness Level
Particle Concentration (≥0.5μm)
Airflow Organization
Positive Pressure Difference (Pa)
A
≤3.5 particles/L
Vertical unidirectional
+10 to +15
B
≤35 particles/L
Vertical unidirectional
+5 to +10
C
≤350 particles/L
Non-unidirectional
+5 to +10
D
≤3500 particles/L
Non-unidirectional
+5 to +10

II. Design Principles and Key Technologies

1.  Site Selection and Layout OptimizationCleanroom sites should avoid pollution sources (e.g., pharmaceutical factories, kitchens, main traffic roads) and prioritize centralized management. In Case 1, a laboratory located near residential areas, despite meeting noise standards, was闲置 due to complaints, highlighting the importance of environmental impact assessment. Centralized layouts reduce pipeline duplication and energy consumption. For example, a hospital centralized clean operating rooms, ICUs, and preparation rooms in one building, saving 30% of costs by sharing purification systems.
2.  Air Purification System DesignAir purification is the core technology, adopting a three-stage filtration system: primary filtration (≥5μm), medium filtration (≥1μm), and high-efficiency filtration (HEPA, ≥0.3μm). In Yiwu Hospital’s design, low-wind-resistance ULPA filters were added to reduce energy consumption and prevent dust accumulation. The air conditioning system must control temperature (22±2°C) and humidity (50%±10%), and incorporate disinfection modules (e.g., UV or ozone).
3.  Material and Equipment SelectionCorrosion-resistant, easy-to-clean, dust-free materials are required, such as stainless steel walls and epoxy flooring. Equipment should include high-sealing automatic doors and embedded lighting to avoid dust accumulation. Case 2 shows that a laboratory using imported sealed doors frequently malfunctioned due to poor maintenance, emphasizing the need to balance performance and local service capabilities.

4. Intelligent and Energy-saving DesignIoT technology enables real-time monitoring of environmental parameters (pressure differential, temperature, filter lifespan) and intelligent adjustments to reduce energy consumption. For example, a hospital achieved 25% energy savings by dynamically adjusting fresh air intake and return air volume. Fire protection systems must be linked to pressure control to prevent positive pressure failure during fires.

空气 拷贝1 拷贝ying


III. Construction and Maintenance Management

1.  Construction Quality ControlThe "three control" principle must be followed: personnel qualification control (certified professionals), material acceptance control (filter grades, sealing materials), and process acceptance control (pipeline pressure testing, concealed engineering records). In one cleanroom, microbial超标 due to poor pipeline sealing increased rework costs by 40%.
2.  Operation and VerificationRegular maintenance includes HEPA filter replacement (every 6-12 months), disinfection equipment calibration, and airflow uniformity testing. A "three-level verification system" is established: static verification after construction (empty environment testing), dynamic verification before use (full-load operation testing), and periodic re-verification (every 2 years). A ICU cleanroom reduced maintenance costs by 15% through regular verification and extended equipment lifespan.

手术室过滤器检查_百度图片搜索 拷贝


IV. Case Study: Optimization of a General Hospital’s Clean Operating Room

Strategies adopted:
●  Site Selection: Avoiding kitchens and preparation buildings, locating on the top floor of the ward building to reduce pollution risks.
●  Technology Upgrade: Using low-energy ULPA filters and intelligent pressure differential control systems.
●  Process Optimization: Dual-channel logistics (clean and dirty passages) to prevent cross-contamination.

● Maintenance Innovation: Implementing VR training to improve staff’s clean operation compliance.Results: Surgical infection rate decreased by 60%, energy consumption reduced by 20%, validating the effectiveness of scientific design.

IMG_20240815_173355 拷贝


V. Conclusion

Hospital cleanroom design requires integrated planning of site selection, technology, construction, and maintenance, achieving safety, efficiency, and economy through standardized processes and intelligent solutions. Future developments will integrate green energy-saving and digital monitoring technologies, promoting sustainable and intelligent environmental management in hospitals.


Hot News

Quick Links

Contact Us

More Links

Product Category

Global operations center

   +86-769-81565768
  +86-769-81565718        
  dirk@dirkbiel.com
   +86-133-9238-6699
    Building 3, No. 9, Daxing Industrial Road, Daini, Shatian Town, Dongguan City (Building C, Tongzheng Wisdom Industrial Park)

Northwest China

  yong.feng@dirkbiel.com
   +86-132-2707-1245
    Xi'an Hi-Tech Zone Caotang Science and Technology Industrial Park

Chendu China

  dirk@dirkbiel.com
   +86-139-2686-3291
    No.289 Wangcong West Road, Gaoxin District (West), Chengdu, China
Message

North America

  +86-769-81565768  
  +86-769-81565778       
  dirk@dirkbiel.com
   +86-133-9238-6699
    Building 3, No. 9, Daxing Industrial Road, Daini, Shatian Town, Dongguan City (Building C, Tongzheng Wisdom Industrial Park)

Europe

  +86-769- 81565798  
  +86-769-81565718        
  winlyn.zhang@dirkbiel.com
   +86-137-2454-4945
    Building 3, No. 9, Daxing Industrial Road, Daini, Shatian Town, Dongguan City (Building C, Tongzheng Wisdom Industrial Park)

Xi'an China

  yong.feng@dirkbiel.com
   +86-132-2707-1245
    Xi'an Hi-Tech Zone Caotang Science and Technology Industrial Park
Copyright © 2023 Dongguan Dirkbiel Environment System Co., Ltd. All Rights Reserved. | Supported by leadong.com